{"product_id":"autoclave-18-litres-classe-b-avec-usb-blanc","title":"Autoclave 18 Liters Class B with USB White","description":"\u003ch2\u003eWhite 18-liter Class B Autoclave with USB\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 159, 148);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(0, 159, 148);\" title=\"Garanties_autoclave_classe_B_1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Garanties_autoclave_classe_B_1.pdf?v=1720080884\" target=\"_blank\"\u003e\u003cstrong\u003eWarranty Details\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003cbr\u003e- The cycle does not start if the door is not properly closed.\u003cbr\u003e- The automated double hydraulic interlocking safety device prevents the door from opening while the chamber is under pressure.\u003cbr\u003e- Safety valves prevent pressure generator and camera issues.\u003cbr\u003e- A safety thermostat prevents overheating in the chamber and generator.\u003cbr\u003e- An automatic safety lock prevents accidental opening of the door during the sterilization process; the protector automatically cuts off electrical power if there is a short circuit or the power supply is not very stable.\u003cbr\u003e- Failure alarm indicates a failed cycle and detailed error code.\u003cbr\u003e- Door alarm indicates that the door is not secured.\u003cbr\u003e- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left; margin: 20px 0;\"\u003e\u003ca style=\"display: inline-block; padding: 10px 20px; background-color: #003959; color: #fff; text-decoration: none; border-radius: 5px; font-family: Arial, sans-serif; font-size: 16px; transition: background-color 0.3s ease;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/mode_emploi_autoclave_18_23L.pdf?v=1713861520\" target=\"_blank\"\u003eUSER MANUAL\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cbr\u003e- Voltage: 220-240 VAC; 50\/60 Hz; 10A\u003cbr\u003e- Chamber dimensions: 247 x 350 mm\u003cbr\u003e- Tray size: 192 x 285 mm\u003cbr\u003e- Circuit breaker: F16A \/ 400V\u003cbr\u003e- 2000W\u003cbr\u003e- Rated power: 1500 VA\u003cbr\u003e- Sterilization temperature: 121 °C \/ 134 °C\u003cbr\u003e- Distilled water tank capacity: 2.5 L\u003cbr\u003e- Operating temperature: 5 °C \/ 40 °C\u003cbr\u003e- Relative humidity: Max. 80%, non-condensing\u003cbr\u003e- External dimensions: 490 x 455 x 600 mm\u003cbr\u003e- Net weight: 47 kg\u003cbr\u003e- Maximum sound level: \u0026lt;70 dB\u003cbr\u003e- Atmospheric pressure: 76 kPa \/ 106 kPa\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMaintenance and error message guide for your \u003cmeta charset=\"utf-8\"\u003esterilizer\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ca title=\"Autoclave : le guide des messages d'erreur\" href=\"https:\/\/www.my-podologie.com\/blogs\/service-apres-vente\/autoclave-icanclave-le-guide-des-messages-derreur?_pos=1\u0026amp;_psq=icanclave\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(0, 159, 148);\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cstrong\u003e\u003cmeta charset=\"utf-8\"\u003e \u003ca title=\"Autoclave Icanclave : maintenance et guide des messages d'erreur\" href=\"https:\/\/www.my-podologie.com\/blogs\/service-apres-vente\/autoclave-le-guide-des-messages-d-erreur\"\u003eIcanclave Autoclave: maintenance and error message guide\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e- Distilled water tank\u003cbr\u003e- LCD screen\u003cbr\u003e- Control panel\u003cbr\u003e- Main switch\u003cbr\u003e- Key for draining distilled and used water\u003cbr\u003e- USB port\u003cbr\u003e- Safety valve\u003cbr\u003e- Ventilation grille\u003cbr\u003e- Locking system\u003cbr\u003e- Power cable\u003cbr\u003e- Label\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003cbr\u003e- Sterilizer\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e- 3 Instrument trays\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e- Tray holder\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e- Extraction clamp\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e- Door adjustment tool\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e- 2 Drain pipes\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e- Door gasket\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e- User manual \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e- 93\/42 \/ CEE Medical devices directive.\u003cbr\u003e- 97\/23 \/ CEE Pressure equipment directive.\u003cbr\u003e- EN 13060 Small steam sterilizers.\u003cbr\u003e- EN 61326, EN 61000 EMC.\u003cbr\u003e- EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e- EN 61010-2-040, IEC 61010-2-040 Special requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e1. Open the door, take out the tools and accessories located in the sterilization chamber, remove the packaging, and clean them.\u003cbr\u003e\u003cbr\u003e2. Plug the power cord into a suitable power source.\u003cbr\u003e\u003cbr\u003e3. Connect the printer (sold separately).\u003cbr\u003e\u003cbr\u003e4. Powering on: the main switch is located on the front, bottom right of the device. Once turned on, the LCD screen will light up, and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time, will illuminate.\u003cbr\u003e\u003cbr\u003e5. Remove the top cover, then fill the distilled water tank. If a beep sounds, it means you have exceeded the permitted water level in the tank. Drain the excess water until the alarm turns off.\u003cbr\u003e\u003cbr\u003e6. Preparing materials for sterilization: place the instruments on the different trays, separating them according to their materials. If the instruments are not stainless steel, use sterilization pouches. These should not be in contact. Ensure that all instruments are placed correctly, so that no water remains in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\u003cbr\u003e7. Select the sterilization program.\u003cbr\u003e\u003cbr\u003e8. Start the sterilization cycle.\u003cbr\u003eAfter selecting the sterilization program, place the instruments on the trays in the chamber using the provided plastic clamp.\u003cbr\u003eOnce the instruments are properly placed inside, close the door. Caution: ensure the door is properly closed, otherwise the autoclave will not function.\u003cbr\u003e\u003cbr\u003e9. Start the sterilization program.\u003cbr\u003ePress the power button; the autoclave will start operating for approximately 30-75 minutes.\u003cbr\u003e\u003cbr\u003e10. End of the sterilization cycle.\u003cbr\u003eOnce the sterilization cycle is complete, the printer (not included) will automatically print the full cycle report.\u003cbr\u003eOnce the pressure has returned to 0, you can open the door and remove the instruments. The autoclave will notify you with an audible signal once the sterilization cycle is complete.\u003cbr\u003eCaution: Use the plastic clamp to remove the instruments.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eIMPORTANT: Do not reuse wastewater after draining the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIt is important to keep the packaging carton in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49677326713159,"sku":"49.003","price":2204.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/67085_3fbc065b-4812-4854-9ef5-fb8b5fe640a8.png?v=1719327967","url":"https:\/\/www.my-podologie.re\/en\/products\/autoclave-18-liters-class-b-with-usb-white","provider":"My Podologie","version":"1.0","type":"link"}